IQORON-S Air Cleaner

The IQORON-S Air Cleaner is a compact single-stage air filtration system designed for stationary applications with light dust loads, such as compressors. With a volume flow range of 4 to 10 m³/min, it combines high power density, compact design, flexible installation and low pressure drop.

Unlike the two-stage models in the IQORON range, the IQORON-S operates without a multi-cyclone pre-separator. Its high-efficiency filter element provides a final separation efficiency of over 99.97%, making it suitable for applications where low airflow restriction is a key selection criterion.

The inline airflow concept allows integration into restricted installation spaces, with both vertical and horizontal mounting options. Front-access servicing with comfort fasteners simplifies filter maintenance.

The IQORON-S operates at continuous temperatures from −30°C to +90°C, with short-term temperature resistance up to +110°C.

  • Single-Stage Air Filtration: High-efficiency filtration without a multi-cyclone pre-separator, designed for stationary applications with light dust loads.

  • High Filtration Efficiency: Achieves over 99.97% final separation efficiency.

  • Low Pressure Drop: Designed for applications requiring low airflow restriction.

  • Compact Inline Design: High power density and inline airflow support integration into restricted installation spaces.

  • Flexible Installation: Suitable for vertical and horizontal mounting, using through-holes and/or threaded inserts.

  • Simplified Maintenance: Front-access servicing with comfort fasteners facilitates filter replacement.

  • Environmentally Conscious Filter Disposal: The IQORON series documentation describes metal-free, fully incinerable filter elements to facilitate disposal.

Technical Features IQORON IQORON-V IQORON-S
Type of Operation Two-stage air cleaner Two-stage air cleaner Single-stage air cleaner
Field of Application Applications with high dust loads, such as agricultural and construction machines Applications with high dust loads, such as agricultural and construction machines and mobile compressors Stationary applications with light dust loads, such as compressors
Volume Flow Range 4–12 m³/min 3–14 m³/min 4–10 m³/min
Operating Temperature Continuous: −30°C to +100°C
Short-term: +120°C
Continuous: −40°C to +100°C
Short-term: +120°C
Continuous: −30°C to +90°C
Short-term: +110°C
Pre-separator Multi-cyclone block (cleanable as required) Multi-cyclone block (cleanable as required) —
Pre-separation Efficiency with Dust Discharge Valve — Up to 90% —
Pre-separation Efficiency with Scavenging (10%) >95% Up to 95% —
Final Separation Efficiency >99.99% >99.99% >99.97%
Dust Discharge Scavenging (e.g. ejector or blower) Dust discharge valve (option: scavenging) —
Installation Inline concept; vertical and horizontal installation possible; mounting with through-holes and/or threaded inserts Inline concept; vertical and horizontal installation possible; mounting with through-holes and/or threaded inserts Inline concept; vertical and horizontal installation possible; mounting with through-holes and/or threaded inserts
Service Concept Side servicing with standard fasteners Front servicing with comfort fasteners: IQORON-V 4.5 and V 7
Side servicing with comfort fasteners: IQORON-V 9 and V 14
Front servicing with comfort fasteners
Selection Criteria High power density, compact design and long service life; scavenging required High power density, compact design, flexibility and long service life; dust discharge via valve does not require scavenging; scavenging as option High power density, compact design, flexibility and low pressure drop

REQUEST INFORMATION OR REQUEST A QUOTE

BORSERINI E-COMMERCE

DOWNLOADS

Description

The IQORON-S Air Cleaner is a compact single-stage air filtration system designed for stationary applications with light dust loads, such as compressors. With a volume flow range of 4 to 10 m³/min, it combines high power density, compact design, flexible installation and low pressure drop.

Unlike the two-stage models in the IQORON range, the IQORON-S operates without a multi-cyclone pre-separator. Its high-efficiency filter element provides a final separation efficiency of over 99.97%, making it suitable for applications where low airflow restriction is a key selection criterion.

The inline airflow concept allows integration into restricted installation spaces, with both vertical and horizontal mounting options. Front-access servicing with comfort fasteners simplifies filter maintenance.

The IQORON-S operates at continuous temperatures from −30°C to +90°C, with short-term temperature resistance up to +110°C.

  • Single-Stage Air Filtration: High-efficiency filtration without a multi-cyclone pre-separator, designed for stationary applications with light dust loads.

  • High Filtration Efficiency: Achieves over 99.97% final separation efficiency.

  • Low Pressure Drop: Designed for applications requiring low airflow restriction.

  • Compact Inline Design: High power density and inline airflow support integration into restricted installation spaces.

  • Flexible Installation: Suitable for vertical and horizontal mounting, using through-holes and/or threaded inserts.

  • Simplified Maintenance: Front-access servicing with comfort fasteners facilitates filter replacement.

  • Environmentally Conscious Filter Disposal: The IQORON series documentation describes metal-free, fully incinerable filter elements to facilitate disposal.

Technical Features IQORON IQORON-V IQORON-S
Type of Operation Two-stage air cleaner Two-stage air cleaner Single-stage air cleaner
Field of Application Applications with high dust loads, such as agricultural and construction machines Applications with high dust loads, such as agricultural and construction machines and mobile compressors Stationary applications with light dust loads, such as compressors
Volume Flow Range 4–12 m³/min 3–14 m³/min 4–10 m³/min
Operating Temperature Continuous: −30°C to +100°C
Short-term: +120°C
Continuous: −40°C to +100°C
Short-term: +120°C
Continuous: −30°C to +90°C
Short-term: +110°C
Pre-separator Multi-cyclone block (cleanable as required) Multi-cyclone block (cleanable as required) —
Pre-separation Efficiency with Dust Discharge Valve — Up to 90% —
Pre-separation Efficiency with Scavenging (10%) >95% Up to 95% —
Final Separation Efficiency >99.99% >99.99% >99.97%
Dust Discharge Scavenging (e.g. ejector or blower) Dust discharge valve (option: scavenging) —
Installation Inline concept; vertical and horizontal installation possible; mounting with through-holes and/or threaded inserts Inline concept; vertical and horizontal installation possible; mounting with through-holes and/or threaded inserts Inline concept; vertical and horizontal installation possible; mounting with through-holes and/or threaded inserts
Service Concept Side servicing with standard fasteners Front servicing with comfort fasteners: IQORON-V 4.5 and V 7
Side servicing with comfort fasteners: IQORON-V 9 and V 14
Front servicing with comfort fasteners
Selection Criteria High power density, compact design and long service life; scavenging required High power density, compact design, flexibility and long service life; dust discharge via valve does not require scavenging; scavenging as option High power density, compact design, flexibility and low pressure drop

Installation and Maintenance Manual

Download

Iqoron

Download

Let's Find the Right Solution Together

We are ready to support your next project

Borserini
Privacy Overview

This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.